Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 10-13, 2020.
Article in Chinese | WPRIM | ID: wpr-781205

ABSTRACT

@#Objective    To assess the feasibility and safety of percutaneous transcatheter closure of atrial septal defect (ASD) guided by transthoracic echocardiography (TTE) in outpatients. Methods    From December 2016 to June 2018, 50 simple ASD patients underwent TTE-guided transcatheter closure in the outpatient operating room of our hospital (a TTE group) including 22 males and 28 females at the age of 16-48 (27.40±6.95) years. Fifty patients with simple ASD treated with the guidance of conventional fluoroscopy during the same period were treated as a control group, including 22 males and 28 females at the age of 15-48 (28.58±6.96) years. Both groups were re-examined by TTE during follow-up at 1 month, 3 months, 6 months and 1 year. Results    The mean age, body weight, the size of ASD and occluder and success rate had no statistical difference between the two groups (P>0.05). Compared with the control group, the TTE group had significantly lower mean operation time (P<0.01) and less cost (P<0.01) since patients need not to be hospitalized. No related complications were found in the TTE group during follow-up. Conclusion    Percutaneous transcatheter closure of ASD guided by TTE appears safe and effective for outpatients, and can significantly reduce the cost.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 462-465, 2018.
Article in Chinese | WPRIM | ID: wpr-749621

ABSTRACT

@#Objective     To analyze the safety and effectiveness of ultrasound-guided thoracoscopic atrial septal defect (ASD) closure. Methods     We prospectively collected the clinical data of 12 patients with ASD treated by ultrasound-guided thoracoscopic ASD closure in Fuwai Hospital from January to September 2017. The characteristics of the patients' ASD and operation, operation safety and effectiveness, postoperative complications and follow-up results were analyzed. Results     Among the 12 patients, 10 were successfully treated with ultrasound-guided thoracoscopic ASD closure. Two patients switched to ASD repair under thoracoscopy-assisted cardiopulmonary bypass. The size of the ASD was 17-40 (27.22±8.97) mm and the size of the occluder was 36 (30-42) mm. The average postoperative length of hospital stay was 6 days. There were no complications such as arrhythmia, bleeding and pericardial effusion after operation. The average follow-up was 6 (3-10) months after the operation. During the follow-up, no Ⅲ-degree conduction block, occluder dislocation, residual shunt or cardiac pericardial effusion was found. Conclusion     Ultrasound-guided thoracoscopic ASD closure is a minimally invasive, safe and effective treatment. This technique provides a new minimally invasive surgical option for patients with large defect diameter and poor edge condition.

4.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 829-833, 2018.
Article in Chinese | WPRIM | ID: wpr-731909

ABSTRACT

@#Objective To analyze the midterm outcome of patients with congenital aortic stenosis undergoing percutaneous balloon aortic valvuloplasty (PBAV) by single echocardiographic guidance. Methods The clinical data of 12 patients with congenital aortic stenosis who underwent PBAV by single echocardiographic guidance at Fuwai Hospital from January 2016 to November 2017 were retrospectively analyzed. There were 7 males and 5 females with an average age of 18.27±15.30 years. The preoperative peak pressure gradient was 61.8–110.0 (80.30±24.50) mm Hg, and 50% of patients had aortic regurgitation. Results All patients successfully underwent PBAV. Aortic annulus diameter was 18.65±3.17 mm and balloon diameter was 17.62±3.77 mm, with balloon diameter to annulus diameter ratio of 0.92±0.07. The peak transaortic gradient was 16-51 (36.72±12.33) mm Hg immediately after procedure, which was significantly different from the preoperation (P=0.000). During the follow-up period, the peak transaortic gradient was 21-58 (37.06±13.52) mm Hg, and there was no significant difference between the follow-up and immediate postoperation (P=0.310). Immediately after procedure and during follow-up, 58% of patients had aortic regurgitation, which was not statistically different from the preoperation (P=0.682). Conclusion Systematic use of Doppler echocardiographic guidance for PBAV is feasible, and that it is associated with a high success rate and a very low complication rate.

5.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 550-554, 2018.
Article in Chinese | WPRIM | ID: wpr-742573

ABSTRACT

@#Objective    To assess the efficacy and safety of percutaneous closure of patent ductus arteriosus (PDA) solely under echocardiography guidance. Methods    We retrospectively analyzed the clinical data of 200 patients who received the percutaneous closure of PDA under echocardiography guidance in Fuwai Hospital from August 2013 to April 2016. According the different approach, they were divided into 2 groups: a femoral artery approach group (n=143) and a femoral vein approach group (n=57). In the femoral artery approach group, there were 42 males and 101 females aged 3.20±5.63 years. In the femoral vein group, there were 10 males and 47 females aged 7.30±11.36 years. All Patients were treated by percutaneous PDA closure solely under echocardiography guidance. The follow-up was performed at one month after the operation by echocardiography, chest radiograph and electrocardiogram. Results    All 200 patients were successfully treated with percutaneous closure of PDA. The patients’ gender, in-hospital stay, rates of occluder  detachment were similar between the two groups (P>0.05). Compared with the femoral vein approach group, the femoral artery approach group had a younger age (3.20±5.63 years vs. 7.30±11.36 years, P<0.001), less body weight (14.25±11.54 kg vs. 24.25±19.14 kg, P<0.001) and shorter diameter of PDA (3.06±0.79 mm vs. 5.93±0.68 mm, P<0.001) and PDA occluders (5.43±1.00 mm vs. 12.14±0.54 mm, P<0.001), but had higher hospitalization expenses (32 108.2±3 100.2 yuan vs. 25 120.7±3 534.1 yuan, P<0.001). In the femoral vein approach group, one patient was closed under radiation guidance because guide wires could not pass through PDA. One patient in the femoral artery approach group suffered from occluder detachment at one day after operation and was cured by transthoracic minimally invasive PDA occlusion. There were no complications of occluder detachment, residual shunt, pericardial effusion or left pulmonary stenosis during the follow-up. Conclusion    Echocardiography-guided percutaneous PDA closure is safe and effective, while the proper interventional approach should be chosen by the anatomical features of PDA.

SELECTION OF CITATIONS
SEARCH DETAIL